Gas supply
connection
requirements
•
Use an elbow
and a %" flare x %" NPT adapter fitting
between
file flexible
gas connector
and the dryer gas pipe, as needed
to avoid kinking.
•
Use only pipe-joint
compound.
Do not use TEFI.ON _'*tape.
•
[his
dryer must be connected
to the gas supply
line with
a listed flexible
gas connector
that complies
with the standard
for connectors
for gas appliances,
ANSI Z21.24
or
CSA 6.10.
Burner input
requirements
Elevations
up to 10,000
ft (3,048 m):
•
The design of this dryer is certified
by CSA International
for use at altitudes
up to 10,000
ft
(3,048
m) above sea level at the Btu rating indicated
on the model/serial
number
plate.
Burner input adjustments
are not required
when the dryer is operated
up to this elevation.
Elevations
above 10,000
ft (3,048
m):
•
When
installed
above 10,000
ft (3,048
m) a 4% reduction
of the burner
Btu rating shown
on the model/serial
number
plate is required
for each
,000 ft (305 m) increase
in
elevation.
Gas supply
pressure
testing
•
The dryer must be disconnected
from the gas supply
piping
system during
pressure testing
at pressures greater than _/2psi.
Dryer
gas pipe
•
The gas pipe that comes
out through
the rear of your dryer has a %" male pipe thread.
A. 1/_ ,, NPT gas supply
line
B. _"
NPT dryer
pipe
*NOTE:
If the dryer is mounted
on a pedestal,
the gas pipe height must be an additional
10. (25.4 cm) or1 _._.._r_,,
/39.4
cm) from the floor,
del)ending
on the pedestal
modeh
For a
garage installation,
the gas pipe height must be an additional
18" (46 cm) from the floor.
Fire Hazard
Use a heavy
metal
vent.
Do not use
a plastic
vent.
Do not use a metal
foil vent.
Failure
to follow
these
instructions
can result
in death
or fire.
WARNING:
lb reduce the risk of fire, this dryer MUST BE EXHAUSTED
OUTDOORS.
IMPORTANT:
Observe
all governing
codes and ordinances.
The dryer exhaust
must not be connected
into any gas vent, chimney,
wall, ceiling
or a
concealed
space of a building.
If using an existing
vent
system
•
C'lean lint from the entire
length of the system and make sure exhaust
hood
is not plugged
with
lint.
•
Replace any plastic or metal foil vent with
rigid or flexible
heavy metal vent.
•
Review Vent system chart. Modify
existing
vent system if necessary
to achieve
the best
drying
performance.
If this is a new
vent
system
Vent
material
•
Use a heavy metal vent. Do not use plastic or metal foil vent.
•
4" (10.2 cm) heavy metal exhaust
vent and clamps
must be used.
4" ( 10.2 cm) heavy metal _'xhaust v_'nt
Vent products
can be purchased
from your dealer or by calling
Maytag Services.
For more
information,
see the "Assistance
or Service"
section.
10
...........