- Press
to confirm the selection made and exit the function.
WARNING:
The list of the configuration programmes can be displayed as follows:
- Select the utility and configuration programmes
- Select the configuration programmes
- Select view other icons
Calibrate when detecting that the setting condition is out-of-tolerance or when the machine
so requires as the E 1 message is displayed.
Calibrate as follows:
1.
select the sensitivity calibration icon
2.
fit a wheel of average dimensions (diameter no less than 14") on the wheel balancer
with only a small unbalance;
3.
perform a spin;
4.
at the end of the spin, fix the calibration weight supplied with the machine on the
swinging unit bell as indicated in figure 23;
5.
perform a second spin;
6
at the end of the spin, change the position of the calibration weight on the shaft as-
sembly bell as indicated in figure 23a;
Operator's manual EM 9280 - EM 9280 C CompactLine
icon;
icon.
Sensitivity Calibration
in the configuration program menu
23
icon;
23a
UK
117