Incorrect dimension settings for an ALU programme. Correct the set dimen-
sions.
A 7
The machine is temporarily unable to select the requested programme.
Perform a wheel spin, then repeat the request.
A 20
Sensor in an incorrect position during calibration.
Bring it to the position indicated and repeat the calibration.
A 26
Programme available only after selecting one of the following programmes:
ALU 1P / ALU 2P / Motorcycle Dynamic / Motorcycle ALU or if selected in the
Motorcycle Programme but with the wheel NOT in the centred position.
A 31
Optimisation procedure (OPT) already launched by another user.
A 41
Contact the technical support centre.
A 52
Procedure opened for assembly of the hub of auto wheel locking system. After
60 seconds, the procedure ends automatically.
A Stp
Wheel stop during the spin phase.
Wheel movement is not integral with swinging unit movement: Check correct
wheel tightening.
A Cr
Contact the technical support centre.
E 1
Absence of sensitivity calibration.
Perform the sensitivity calibration procedure.
E 2
Error condition during sensitivity calibration.
Repeat sensitivity calibration paying attention to the first spin, which must
be performed with the wheel as in the successive spins.
Take particular care NOT to knock the machine during calibration.
E 3 I/E 2/3 Error condition at the end of sensitivity calibration. Repeat the calibration, if
the message persists perform the following checks:
• Correct sensitivity calibration procedure;
• Correct fastening and position of the calibration weight;
• Mechanical and geometric condition of the calibration weight;
• Geometry of the wheel used.
E 4
a) External mechanical sensor calibration error.
Calibrate the external mechanical sensor.
b) if the error continues after calibrating the external mechanical sensor or
the external mechanical sensor is not present, or there is a distance-diameter
measuring sensor fault, call the technical support centre.
E 6
Error condition when executing optimisation programme.
Repeat the procedure from the beginning.
a) Mechanical width sensor not in the rest position when machine was
E 12
switched on. Switch off the machine, return the sensor to the correct position
and switch back on. If the error persists, contact the technical support centre.
b) External mechanical sensor not present or faulty. Visualisation of this error
can be disabled by performing the following procedure:
- Select the External MECHANICAL sensor calibration icon and press ENTER
.