Automatic Position Search (RPA) Configuration
Enables/disables the automatic positioning of the wheel at the end of the spin. After the
list of the setting programmes is displayed, proceed as follows:
- Select the Automatic position search configuration icon
The following icons are displayed:
RPA OFF; disables the automatic position search procedure.
RPA ON; enables the automatic position search procedure.
- Press the Enter button to select the icon desired
- Press the Exit button to save the setting and exit
The selection can also be seen in the working screen status line.
Selection of adhesive weights application position
To access this programme you must:
- select the Utility programmes icon,
- select the configuration programmes icon
- Three icons will appear on the display that represent the possible positions, as shown
below:
H12: the balancing weight must always be applied in the 12 o'clock position regardless of
the type of balancing programme selected or the type of weight to be applied (adhesive
or spring);
LASER: The adhesive balancing weight is to be applied in correspondence of the laser line,
while, the spring weight, again at 12 o'clock (Table A);
CLIP: The adhesive balancing weight is to be applied through the use of small hand-carrier
weights in ALU1P ALU2P and programs, while, in all other programs, hours 12. The spring-
loaded weight always at 12 o'clock
- Select the desired position with the cursor keys. The selected icon is enabled if it is in
the following configuration:
- Press the Exit button to save the setting and exit
The selected configuration is displayed on the status bar in the working environment.
Operator's manual EM 9280 - EM 9280 C CompactLine
.
.
.
.