Installation • Swimming Pool Pump Suction Connection
Typical Swimming Pool
Isolation
Valve
Return to Pool -
One size larger
than Pump Discharge
port to reduce friction
All suction outlets must have
correctly installed, screw-fastened
covers in place.
At least two hydraulically balanced main drains
for each pump suction line. Main drains must be
at least three feet apart, nearest point to nearest
point.
The pump suction system must provide protection
against the hazard of suction entrapment or hair
entrapment/entanglement. All suction outlet covers
must be maintained. They must be replaced if
cracked, broken, or missing.
If 100% of the pump's flow comes from the main
drain system, the maximum water velocity in the
pump suction hydraulic system must be six feet
per second or less even if one main drain (suction
fitting) is completely blocked.
Short length of straight
pipe after reducer.
( 2 times pipe
diameter minimum )
Eccentric Reducer
flat side up.
Suction
Gauge
See
foundation
section.
Straight run, as short
as possible but at least 6 times the
pipe diameter ("D") after strainer
to stabilize flow.
Flow-Through
Strainer
No shutoff valve
betweenTee and
Main Drains
The system must not be able to operate with the
pump drawing water from only one main drain
(that is, there must be at least two main drains
connected to the pump whenever it is running.)
However, if two main drains run into a single
suction line, the single suction line may be
equipped with a valve which will shut off both main
drains from the pump.
Flow
Through
Skimmer
Equalizer
Fitting
To Pump
Suction
Isolation
Valve
Support pipe
as required
NOTICE: All connections
must be air tight.
Not
to
Scale
10
Standard
or long
radius
elbow.
3080 1097