Lavorwash MYSTIC Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
This device enables the machine's by-pass op-
eration through automatic water discharge
whenever it reaches a temperature of nearly
60°C and cooling working components.
CAUTION: appliances that are not pro-
vided with this disposal must not oper-
ate for more than 2 minutes with released
gun. Recycled water raises its temperature
remarkably causing great damages to the
pump.
>
GUN SAFETY DEVICE
Whenever the machine has to be stopped, it is
important to engage the safety catch on the
gun so that it cannot be operated accidentally.
>
MAINTENANCE
IMPORTANT: Before doing any work on
the cleaner, discharge the pressure and
disconnect the electricity and water
supplies.
CHECKING THE PUMP OIL LEVEL
Check the oil level periodically. The oil must
be changed for the first time after 50 working
hours, with subsequent changes every 500
hours. Use oil SAE 20/30 (750 gr).
CHECKING THE WATER INTAKE FILTER
Inspect and clean the water intake filter on the
intake union periodically. This is important to
prevent fouling which may impair operation of
the pump.
REPLACING THE SPRAY ROD NOZZLE
Replace the nozzle when the pressure drops
below the normal values.
ELECTRIC MOTOR
If the motor malfunctions, it cuts out. Wait 5-10
minutes before restarting. If the problem per-
sists, refer to the "TROUBLESHOOTING" section.
If you are still unable to eliminate the problem,
stop using the machine and contact an Author-
ized Service Centre.
ELECTRICAL CORD
WARNING: Take care not damage the elec-
tric cable. Have a damaged power cord re-
placed immediately by an authorized serv-
ice point or an electrical specialist.
>
ELECTRIC DIAGRAM
See illustrations.
>
WATER DIAGRAM
See illustrations.
>
TROUBLESHOOTING
Before doing any work on the machine, discon-
nect the electricity and water supplies and dis-
charge the pressure. Proceed systematically to
identify faults following the chart below; if you
are still unable to eliminate the problem, call in
the Authorized After-Sales Service.
Fault
Cause
Repair
23
When switch "ON" the ma-
chine will not start work-
ing
• Plug not properly inserted
in socket.
• Electric socket is faulty.
• The main voltage is insuf-
ficient.
• The pump is stuck.
• Gauge of extension lead
not sufficient.
• Fit plug in power socket
correctly.
• Have
electrical
checked.
• Have a check made on the
suitability of the mains
system.
• Turn switch to ON while
keeping nozzle trigger
pressed; if problem per-
sists, contact an author-
ised service centre.
• Refer to maintenance sec-
tion.
EN
socket

Publicidad

Tabla de contenido
loading

Tabla de contenido