General safety advice
Please read carefully!
Target group
This operator system may only be installed, connected and put into operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed. Disregarding these warnings may lead to personal injury
or material damage. If this advice is disregarded, the manufacturer will not be liable for damages that might occur.
Batteries, fuses and bulbs are excluded from warranty. To avoid installation errors and damage to the door and operator
system, it is imperative that the installation instructions are followed.
The system may only be used after thoroughly reading the respective mounting and installation instructions.
The installation and operating instructions are to be given to the door system user, who must keep them safe.
They contain important advice for operation, checks and maintenance. This item is produced according to the directives and standards
mentioned in the Manufacturer's Declaration and in the Declaration of Conformity. The product has left the factory in perfect condition
with regard to safety. Power-operated windows, doors and gates must be checked by an expert (and this must be documented) before they are put into
operation and thereafter as required, but at least once a year.
Correct use
The operator system is designed exclusively for opening and closing garage doors.
The operator must be used in a dry place.
The maximum push and pull force must be observed.
Door requirements
The door must:
- stand still alone (by balance of springs),
- run smoothly.
Beside the advice in these instructions, please observe the general safety and accident prevention regulations!
Our sales and supply terms and conditions are effective.
Information on installing the operator system
• Ensure that the door is in good mechanical condition.
• Ensure that the door can stop in any position.
• Ensure that the door can be easily moved in the OPEN and CLOSE directions.
• Ensure that the door opens and closes properly.
• Remove all unnecessary components from the door (e.g. cables, chains, brackets).
• Render any installations inoperable that will no longer be needed after the operator system has been installed.
• Before commencing cabling works it is very important to disconnect the operator system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately. The controls voltage is 24 V DC.
• Install the operator system with the door in the CLOSED position.
• Install all the impulse transmitters and control devices (e.g. remote control buttons) within sight of the door and at a safe distance from the moving parts
of the door. A minimum installation height of 1.5 m must be observed.
• Permanently fix the warning signs, which advise of the danger of becoming trapped, at conspicuous locations.
• Ensure that no part of the door extends across public footways or roads when the installation is complete.
Information on commissioning the operator system
After initial operation, the persons responsible for operating the door system, or their representatives must be familiarised with the use of the system.
• Make sure that children cannot access the door control unit.
• Before moving the door, make sure that there are neither persons nor objects in the operating range of the door.
• Test all existing emergency command devices.
• Never insert your hands into a running door or moving parts.
• Pay attention to any parts of the gate system that could cause crushing or shearing damage or accidents.
The EN 13241-1 regulations must be observed.
Information on servicing the operator system
To ensure proper operation, the following items must be checked regularly and repaired if necessary.
Before any works to the door system are undertaken, the operator system must be disconnected from the mains.
• Check once a month to ensure that the operator system reverses if the door encounters an obstacle.
Depending on the operational direction of the door, place a 50 mm high/wide obstacle in its path.
• Check the settings of the OPEN and CLOSE automatic cut-out function.
• Check all movable parts of the door and operator system.
• Check the door system for signs of wear or damage.
• Check whether the door can be easily moved by hand.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
EN
21