QUICK PROGRAMMING EN05 - EN10
1. With the door in the closed position, power up the actuator.
LED no.8, which indicates the presence of power, and LED no.4, which indicates
that the door is closed, must both be on
2. To start quick programming, press key P until the three LEDS no.8 - no.1 – no.2
at the top light up.
3. Release key P and press "+". Keep "+" pressed until the door is fully open. While
the door is opening the 3 LEDs will blink.
Make any corrections that are necessary using the "-" and "+" keys.
4. Press key P to save the opening limit stop.
The three red LEDs no.4 – no.5 – no.6 at the bottom light up.
5. Release key P and press "-". Keep "-" pressed until the door is fully closed. While
the door is closing the 3 LEDs will blink. Make any corrections that are necessary
using the "+" and "-" keys.
6. Press key P to save the closing limit stop.
The red LEDs no.6 – no.7 (blinking) – n°8 light up.
7. Press the radio control key.
LED no.7 blinks rapidly to indicate that the code has been saved.
8. Press key P to save the radio code and keep it pressed for 1 second.
All of the LEDs switch on and off in anti-clockwise order and the actuator exits
programming mode and reverts to the start condition (LEDs no.8 and no.4 on).
9. To check correct operation, open and close the door by pressing the remote
control key.