Menu 1: Automatic closing timer
Door open
Warning
duration
time
Level 4 – Remote programming
Menu 1: Impulse
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
Menu 2: Intermediate position
LED 7 flashes slowly -> press the hand transmitter button -> LED 7 flashes quickly
Level 5 – Special function
Menu 1: Programmable impulse input – Terminals 1/2
Menu 4: Lighting duration (in seconds)
Menu 1: Programmable impulse input – Terminals 1/2
A1- Impulse (normally open contact only)
B1- Automatic On/Off (normally open contact only)
C1- Drive system stops and reverses (only in CLOSE direction – normally closed contact only / for the programming of the ELVOX photocell)
D1- Impulse OPEN (induction loop – normally open contact only)
E1- Stop (normally closed contact only)
Level 8 – System settings
Menu 1: Photocell
Menu 1: Photocell (only version with testing)
A1- Operation without photocell
B1- Operation with system photocell (XP020)
EN
Signal light
Automatic closing timer deactivated
flashes
flashes
flashes
Closes after the photocell barrier has been driven past
flashes
Closes after the photocell barrier has been driven past
on
on
on
Closes after the photocell barrier has been driven past
on
Closes after the photocell barrier has been driven past
Other functions