6.1.c - PLANNED MAINTENANCE WORKS
DANGER
These operations must be carried out by special-
ized technical staff with the machine cold and the
power cut.
Every 200 hours
6.1.c.a - Rack greasing (Fig. 2)
Remove the rear panel (1) by undoing the relative
screws.
Grease the rack (2) using a cloth and Black High
Temperature Grease.
Refit the panel (1).
6.1.d - MAINTENANCE OPERATIONS AS NEEDED
DANGER
These operations must be carried out by special-
ized technical staff with the machine cold and the
power cut; if the power needs to be on, operate with
extreme care.
6.1.d.a - Checking parallelism between the two
dishes (Fig. 3)
Lower the upper dish (1) as close as possible to the
lower dish (2) but without them touching; adjust the
thickness using the knob (3) then turn off the machine
by setting the switch (4) to "0".
Use a 0.1 to 1mm thickness gauge and check the
distance between the two dishes (1) and (2) at the
four points (5).
If the distance needs to be adjusted, loosen the lock
nut (6) and loosen or tighten the screw (7), then
tighten the lock nut.