Hitachi Koki CR 18DL Manual De Instrucciones página 16

Ocultar thumbs Ver también para CR 18DL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
Before
Charge
charging
status
lamp (RED)
While
charging
Charging
complete
Charging
impossible
Overheat
Overheat
lamp
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling
fan.
Regarding the temperature of the rechargeable battery.
The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.
Rechargeable batteries
EBM1830, BCL1815
4. Disconnect battery charger from the receptacle.
CAUTION:
Do not pull the plug out of the receptacle by pulling on the cord.
Make sure to grasp the plug when removing from receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the battery from the battery charger.
<UC18YGL2>
1. Insert the plug of battery charger into the receptacle.
When the plug of battery charger has been inserted into the receptacle, pilot lamp will
blink in red. (At 1-second intervals)
16
Table 2
Indications of the pilot lamp
Blinks
Lights for 0.5 seconds. Does not light
(RED)
for 0.5 seconds. (off for 0.5 seconds)
Lights
Lights continuously
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.1 seconds. Does not light
Flickers
for 0.1 seconds. (off for 0.1 seconds)
(RED)
Lights
Lights continuously
(GREEN)
Table 3
Temperatures at which the battery can be recharged
32°F — 122°F (0°C — 50°C)
Malfunction in the
battery or the charger
Battery
overheated.
Unable
to
charge
(Charging will commence
when battery cools).

Publicidad