4.5 "HAMMAM/ TURKISH BATH" BUTTON

Press the "Hammam/Turkish bath" button to start generating steam.
Steam will start coming out of the diffuser inside the Hammam/Turkish bath after about 15/20 minutes (the exact
time depends on the electric power and the position of the Nuvola generator).
PLEASE NOTE: when it starts working for the first time, before it emits steam, the Nuvola generator will
automatically clean the boiler, a process that takes about 15
The temperature setting button will flash to indicate this phase.
If you press the "Hammam/Turkish bath" button while it is functioning, this will interrupt steam emission.
PLEASE NOTE: after steam emission has been interrupted for about 30 minutes, the Nuvola smart electronic
system automatically switches to the boiler empty and clean function, a feature that enables the generator to
work for a long time without the need for any maintenance.
This operation takes about 15 minutes and leaves the Nuvola generator clean and ready for the next use.
During automatic rinsing, the temperature setting button will flash.
The "Hammam/Turkish bath" boiler switch-off function immediately stops steam production.
If the Hammam is not started up after 30 minutes, the generator will switch to boiler-empty mode, otherwise,
if the boiler is still full and hot, pressing the "Hammam/Turkish bath" button will produce steam in a short time.
DO NOT CUT OFF THE ELECTRIC POWER TO THE GENERATOR for about an hour after steam emission has been
interrupted.
The steam generator automatically performs regular checks on the electric valves in order to keep these in
working order and to maintain the water level in the outlet siphon.
During these checks, users may be aware of noises coming from the steam generator.