Emptying the chip basket (optional)
Figure 8
1
Chip basket
2
Container clamp
WARNING!
Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Lift the container with a suitable lifting device.
Open the container clamp (2) and lift the vacuum cleaner
motor head.
Engage the motor head handle to the safety hook (3 -
figure 9) by paying attention to the machine stability.
Ensure that the motor head is fully lifted and locked into
its position with the stop hook (3 - figure 9).
Remove the chip basket (1).
Empty the container and clean it (see "Cleaning the
containers" paragraph).
Place the chip basket back in position, making sure it is
correctly positioned.

Container Removal

Figure 9
Open the container clamp (1) and lift the vacuum cleaner
motor head (2).
Engage the motor head handle to the safety hook (3) by
paying attention to the machine stability.
Ensure that the motor head is fully lifted and locked into
its position with the stop hook (3 - figure 9).
Remove the float holding plate or, if equipped, the chip
basket.
Remove the container using the handles (4).
Reinstall the container properly by engaging the dowel
pins (5).
Disengage the safety hook (4) to release and reposition
the motor head.

At the end of a cleaning session

Turn off the vacuum cleaner and remove the plug from
the socket.
Wind the electric connection cable.
Empty the container as described in the "Emptying
the containers" paragraph. Clean the vacuum cleaner
as described in the "Maintenance, cleaning and
decontamination" paragraph.
Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
08/2018
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all the maintenance operations, including
cleaning and replacing of the safety filters.
■ To allow the user to carry out the maintenance
operations, the vacuum cleaner must be
disassembled, cleaned and overhauled as far as
is reasonably possible, without causing hazards
for the maintenance staff or other people. The
suitable precautions include decontamination
before disassembling the device, adequate
filtered ventilation of the exhaust air from the
room in which it is disassembled, cleaning of the
maintenance area and suitable personal protection.
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.
■ Carry out a technical inspection at least once a
year, for example: check the filters to find out
whether the air-tightness of the vacuum cleaner
has been impaired in any way and make sure that
the electric control panel operates correctly. This
inspection must be carried out by the manufacturer
or by a qualified technician.
WARNING!
Use only genuine spare parts supplied and authorized
by the manufacturer.
9
VHO200
GB
C402

Publicidad

Tabla de contenido
loading