4.5
Overview of setting and read-out options
Menu
Menu title
Adjustable
operating values
1
HK2
Operation mode
2
Parameter
Heating
Target room tem-
perature
Night set back
temp.
HK2
Operation mode
3
Parameter
Cooling*
AT switch-off
threshold
ÆAT 24h cooling
start
ÆAT 24h current
Heating demand
Stand-by
Cooling demand
Hot water
Operation mode
4
Parameters
Max. hot water tem-
perature (only
appears if auxiliary
heater is enabled.)
Min. hot water tem-
perature
CURRENT cylinder
temperature
HK2
Day of week/block
5
Time pro-
gramme
heating
1 Start/end time
2
3
4.2 Overview of setting and read-out options in the menus
Operating instructions geoTHERM 0020051578_03
Remarks
Read out the operating
condition and warnings
for the system.
Set operation mode for
heating mode.
Set room temp. setpoint
for heating mode.
Define night set back temp.
for periods between the time
windows for heating mode.
Set operation mode for
cooling mode.
Define temperature thresh-
old for locking
out heating mode
(summer function)
Define average outside tem-
perature from which cooling
is activated.
Read currently calculated
average outside tempera-
ture.
Read status information
Set operation mode for
hot water handling.
Set room temp. setpoint
for DHW loading.
Set room temp. setpoint
for DHW loading.
Read current hot water cyl-
inder temperature.
Select day of week/block
of days (e.g. Mo-Fr).
Three time periods available
per day or block of days
Unit
Min.
Max.
Incre-
value
value
ment/
selection
option
°C/bar
-
Auto; Eco;
Heating;
Energy
sav; Off
°C
5
30
1.0
°C
5
30
1.0
-
Auto;
Cooling;
Off
°C
1.0
°C
1.0
°C
-
-
Auto; On;
Off
°C
53
75
1.0
°C
30
48
1.0
°C
-
Hours/
10 min
min-
utes
Operation
4
Factory
Your
setting
own
set-
ting
Auto
20
15
Auto
20
23
Auto
60
44
-
21
GB