Worn-Out Products - Sundstrom SR 500 EX Instrucciones De Uso

Ocultar thumbs Ver también para SR 500 EX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
7. Approval
• The SR 500 EX in combination with face shield
SR 540 EX, hoods SR 520, SR 530, SR 561,
SR 562, SR 601, SR 602 or helmet with visor
SR 580 is approved in accordance with
EN 12941:1998, class TH3.
• The SR 500 EX in combination with full face mask
SR 200 is approved in accordance with
EN 12942:1998, class TM3.
• The SR 500 EX is ATEX approved (Directive
2014/34/EU) in accordance with EN 60079-0:2012,
EN 60079-11:2012, EN 13463-1:2009.
• The SR 500 EX is IECEx approved in accordance
with IEC 60079-0:2011 and IEC 60079-11:2011.
• The SR 500 EX conforms to the requirements of
EN 50081-1 Emission and EN 61000-6-2 Immunity,
which makes the fan conform to EMC Directive
2014/30/EU.
The PPE Regulation (EU) 2016/425 type approval has
been issued by Notified Body 0194. For the address,
see the reverse side of the user instructions.
The ATEX and IECEx type approval certificates have
been issued by Notified Body No. 0470.
NEMKO AS, Gaustadalléen 30, N-0314 Oslo, Norway.
The EU declaration of conformity is available at www.
srsafety.com
ATEX-codes:
SR 500 EX combined with hoods SR 520, SR 530,
SR 561, SR 562, SR 601, SR 602 or full face mask
SR 200 with glass visor:
II 2 G Ex ib IIB T3 Gb
II 2 D Ex ib IIIC T195°C Db
Ta = -10°C to +40°C
SR 500 EX combined with face shield SR 540 EX,
helmet with visor SR 580 or full face mask SR 200
with PC visor:
II 2 G Ex ib IIA T3 Gb
II 2 D Ex ib IIIC T195°C Db
Ta = -10°C to +40°C
Key to ATEX markings
Explosion protection mark.
II
Equipment group (explosive atmospheres
other than mines with fire damp).
Equipment category (2 = High level of
2 G
protection for Zone 1, G = Gas).
2 D
Equipment category (2 = High level of
protection for Zone 21, D = Dust).
Ex
Explosion protected.
ib
Type of protection (Intrinsic safety).
IIA
Gas group (Propane).
IIB
Gas group (Ethylene).
Dust material group (zone with conductive
IIIC
dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Gb
Equipment Protection Level, gas (high
protection).
Equipment Protection Level, dust (high
Db
protection).
Ta
Ambient temperature limits.
IECEx codes:
SR 500 EX combined with hoods SR 520, SR 530,
SR 561, SR 562, SR 601, SR 602 or full face mask
SR 200 with glass visor:
Ex ib IIB T3 Gb
Ex ib IIIC T195°C Db
SR 500 EX combined with face shield SR 540 EX,
helmet with visor SR 580 or full face mask SR 200
with PC visor:
Ex ib IIA T3 Gb
Ex ib IIIC T195°C Db
Key to IECEx markings
Ex
Explosion protected.
ib
Type of protection (Intrinsic safety).
IIA
Gas group (Propane).
IIB
Gas group (Ethylene).
Dust material group (zone with conductive
IIIC
dust).
T3
Temperature class, gas (maximum surface
temperature +200°C).
T195°C Temperature class, dust (maximum surface
temperature +195°C).
Gb
Equipment Protection Level, gas (high
protection).
Equipment Protection Level, dust (high
Db
protection).
Australian StandardsMark
The fan SR 500 EX is tested and certified to comply to
AS/NZS 1716:2012. The StandardsMark is issued
under licence by SAI Global Certification Services Pty
Limited Lic No.766 (ACN 108 716 669) ("SAI Global").

8. Worn-out products

The fan unit contains a circuit board with electronic
components, a small proportion of which comprise
toxic substances. The battery contains no mercury,
cadmium or lead, and is therefore not regarded as
environmentally harmful waste. For proper handling,
collection and recycling, worn-out fans should be
handed in to a recycling centre, where they are
accepted free of charge. In some countries, you may
hand in your products as an alternative to the sales
outlet if a new equivalent product is bought. If you
handle the disposal correctly, valuable resources will
be saved and possibly negative effects on human
health will be prevented. Contact the local authorities
for information on the location of your nearest
recycling centre. Unsatisfactory disposal of these
products may be punishable by a fine.
45

Publicidad

Tabla de contenido
loading

Tabla de contenido