Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
COMPACT 3.0

Control Panel

5
4
1.- On/off: Switching the unit On - Off and mode selection F4 / F0 / F1 / F2 / F6
2.- Temperature selector (15/ 27 ºC - 59/80º F), Remote control programmation,
Farenheit degrees and Air Speed: Ambient temperature control and blower speed
(between 1st and 5th speed) manual mode only.
3.- Display: Screen showing the function selected and the status of the equipment.
4.- Led : On - indicates intermediate power f0 , f4
5.- Led : On - indicates maximum power P0 , P4
When connecting, the unit checks the LEDs, displays 88--Sc 30 and goes off.
Special display messages (please check Trouble Shooting):
Lb: " Low battery (the unit will beep for a few moments and then go off).
EO :
Poor contact of the return air sensor cables, or return air sensor faulty.
E2 :
Condenser fan or centrifugal blower failure.
E6 :
Poor anti-freeze sensor cable contact, or anti-freeze sensor faulty.
E9 :
Compressor protection (cabin tilted).
Turning the Equipment On
To turn the Compact 3.0 unit on, press the On/off key
on the F4 Function (Automatic Function).
To change the function, hold down the On/Off key
displayed, release the key on obtaining the desired function.
ºC
+
3
ºF
TEMP
9
2
-
. The unit will always start up
. The different functions will be
EN
®
ON/OFF
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ntg compact 3.010012381531001653055Bycool compact 3.0