COMPACT 1.4
Control panel
2
1.- On/off switch on /off the unit and functioning selection mode.
2.- Indicate the compressors functioning.
3.- Display: Screen where it shows the slected functioning and condition of the unit.
4.- Temperature selectors : To select the surrounding temperature and the blower speed
(this only in manual mode) , remote control programmation and Fahrenheit degrees.
• When you connect, the engine make leds control and you can read 88--bd on the display
and the engine swith off.
Special display symbols (please see troubleshooting manual):
Lb
: Low battery.
EO:
Poor contact of wires on return air sensor or return air sensor faulty.
E2:
Failure condenser fan centrifugal or blower.
E9:
Compressor protection (cabin tilted).
Remote control
Remote control functions:
Switching on /off of equipment.
1
Blower speeds control.
2
Temperature control.
3
How to activate remote control:
In order to activate remote control, while equipment is switched off, push key
C
panel until
flashes on display. When it stops flashing, push the On/off key on in the remote
control. You will have to do it within 30 seconds or else you will have to repeat the whole
operation.
ºC
3
ºF
TEMP
9
+
4
-
1
2
EN
®
1
ON/OFF
3
-
from control