SYMPTOMS
POSSIBLE CLAUSES
The external
synchronization source is
faulty.
The RT9s gives
an incorrect time.
An offset is applied to the
time.
The RT9s is not
connected to the network.
Impossible to
add a new event
to the calendar
The IP address of the
manager.
RT9s is not the one
configured in the calendar
manager.
A "danger" sign
appears next
Communication problem
to a calendar in
between the RT9s and the
Mozilla Sunbird
computer running Mozilla
and it is not
Sunbird.
possible to add
or edit an event.
The RT9s does
The antenna is perhaps
not synchronize
not oriented properly.
in TDF/DCF.
124
SOLUTIONS
Correct the fault in the synchronization source,
or force the use of the internal clock via the
«time base» page in the web interface:
«force RtC» box.
Then enter the exact time on the same page.
In the "time base» page in the web interface,
check whether time zone and DST policy are
set correctly.
Check the network connection between the
RT9s and the computer used.
Check the IP address setting of each calendar
in the manager. Correct where necessary (by
manual setting or with the automatic setup
software)
Right-click the relevant calendar, and click
«Properties.»
Uncheck the «Read Only» box.
Reload the calendars by right-clicking a blank
area in the calendar pane, and then selecting
«Reload remote calendars»
Orient the antenna again using the LED: it
must flash regularly (once a second in DCF).
MDE-RT9s-3079V1.0