Resistance
Ranges
Resolution
Accuracy
Open circuit volts
Overload protection
Capacitance
Ranges
Resolution
Accuracy
Test voltange
Test Frequency
Input protection
Temperature
Ranges
Resolution
Accuracy
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
100 mΩ
±(1.0 % rdg + 4 dgts) on 400Ω to 4MΩ ranges
±(2.0 % rdg + 5 dgts) on 40MΩ range
-0.45 V dc typical, (-1.2 V dc on 400Ω range)
1000 V dc or 750 V ac rms
4μF, 40μF, 400μF, 4000μF
1 nF
±(5.0 % rdg + 10 dgts) on 4μF range
±(5.0 % rdg + 5 dgts) on 40μF to 400μF ranges
±(5.0 % rdg + 15 dgts) on 4000μF range
< 3.0 V
25Hz
0.315A/1000V fast blow ceramic fuse 6.3×32mm
on μA/mA input
-20 °C to 1000 °C, -4 °F to 1832 °F
1 °C, 1 °F
±(2.0 % rdg + 4 °C) -20 °C to 10 °C
±(1.0 % rdg + 3 °C) 10 °C to 200 °C
±(3.0 % rdg + 2 °C) 200 °C to 1000 °C
±(2.0 % rdg + 8 °F) -4 °F to 50 °F
±(1.0 % rdg + 6 °F) 50 °F to 400 °F
±(3.0 % rdg + 4 °F) 400 °F to 1832 °F