Operating Instructions SATA FDG
EN
Attention!
Damage from incorrectly conditioned compressed air
Incorrectly conditioned compressed air can damage the pneumatic mo-
tor.
→ The pneumatic motor must be operated with technically clean, oiled
compressed air. The oil rate is approx. 1 drop acid-free oil per minute.
Attention!
Damage from excessive speed
The agitator can be damaged by excessive speed.
→ Never let the agitator run without load. Do not select the speed to be
any higher than necessary for perfect agitation.
The air micrometer [11-2] / [12-2] / [15-1] / [16-1] permits fully variable
speed adjustment for the agitator.
■ Turn to the left to increase the agitator speed.
■ Turn to the right to reduce the agitator speed.
Motor driven agitator
Attention!
Damage from overheating
The electric motor can be damaged if the temperature is too high.
→ Please ensure that the ventilation slots of the motor are not obstruct-
ed while the agitator is in use.
■ Switch the electric agitator on and off with the external control.
10.2. Connect up the material and spraying air supply
Warning!
Risk of injury from material and compressed air pipes that
have not been connected
Leaking material and incorrectly connected compressed air pipes can
cause injuries.
→ Check that the material and compressed air pipes are firmly fitted.
■ Open compressed air supply ball valve [3-9] / [4-9] / [5-2] /[6-1].
Variant with single pressure reducer
■ Open spraying air ball valve [3-7] / [5-4].
134