PARTS OF THE TOOL
Identification plate
Compressed air on/off lever
Safety lever
Compressed air connection with 1/4" thread
Toolholder pincer
STARTING UP
Before starting-up the tool, ensure that:
- the packaging is complete and does not show signs of having
been damaged during storage or transport;
- the tool is complete; check that the number and type of
components comply with that reported in this instruction
booklet;
- the available compressed air production and distribution plant is
capable of satisfying the requirements reported on the tool's
identification plate reproduced and explained on page 11.
ASSEMBLING THE TOOL
Assemble the compressed air connection by screwing it into its
seating.
COMPRESSED AIR CONNECTION
The tool is supplied without the compressed air connection; the
user can use either a quick release coupling or hose type
connection according to his needs, purke they have an hole of air
passing mm. 8. In the latter case the air line must be fixed to the
nozzle by a hose clip.
FITTING TOOLS
Insert the tool shank into the pincer then tighten it using the ope-
rating key.
BEFORE STARTING THE TOOL
Ensure that:
- the compressed air feed line and connection are in perfect
working order;
- the start lever is working properly. This must be done with the air
supply switched off;
- all the components of the tool are mounted correctly and do not
show any signs of damage.
STARTING AND STOPPING
- Starting: push the control lever forward towards the body of the
tool and keep it pressed. When moving the control lever it is
necessary to move the safety lever at the same time topermit the
control lever to move.
- Stopping: release the control lever.
TEST RUN
Start the tool and check that there are no unusual vibrations and
that the sanding disk is firmly held.
Otherwise switch-off the tool immediately and eliminate the
.
cause