Electric Heating Toggle; Locating The Connecting Box For The Connection Cable In The Sauna Room - Helo SAGA ELECTRO Serie Instrucciones De Uso E Instalación

Sauna electric
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
Installation and User Manual SAGA ELECTRO

3.4 Electric heating toggle

The electric heating toggle applies to homes with an electric heating system.
The contactor case has a connection (marked 55) for controlling the electric heating toggle.
Connector 55 and the heating elements are simultaneously live (230V). Refer to the contactor case operating manual for
more specific instructions.
Power
Sauna heater's
connection cable
H07RN-F /
60245 IEC 66
mm
400 – 415V 3N~
kW
16
5 x 6
16
2x 5 x 2,5
20
2x 5 x 2,5
24
2x 5 x 6
Table 1 Connection cable and fuses
Image. 2 Location for the connection box

3.5 Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance, see table 2.
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
Fuse
connection cable
2
A
3 x 25
2x 3 x 16
2x 3 x 16
2x 3 x 25
A
A
Fuse
Sauna heater's
H07RN-F /
60245 IEC 66
2
mm
230V 3~
A
--------
--------
2x 4 x 6
2x 3 x 25
2x 4 x 6
2x 3 x 35
2x 4 x 6
2x 3 x 35
A
A
3.
2.
Fuse
Sauna heater's
connection cable
H07RN-F /
60245 IEC 66
2
mm
230-240V 1N~/2~
A
--------
------
--------
------
--------
------
--------
------
1.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido