tau K580M Guía Para La Instalación página 15

Ocultar thumbs Ver también para K580M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
2
2 / 4 STROKE
OPENING
3
PHOTOCELLS
OPERATION
NO
4
REVERSE
PRE-
5
FLASHING
PHOTOCELL
6
TEST
7 - 8 2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7 Dip 8 Function
Off
Off
Off
On
On
Off
On
On
GATE
9
TYPE
OPENING
10
DIRECTION
SETUP
ENCODER
11
NOTE: moving DIP 11 from ON to OFF (or vice versa), learning process has to be
initialized again.
SENSITIVE
12
EDGE
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmers FR and SENS) gets activated dur-
ing an opening manoeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeu-
vre, the gate opens fully.
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
with automatic closing enabled, a sequence of open/close commands
On
causes the gate to OPENCLOSE-OPEN-CLOSE etc (see also dip switch 4).
in the same conditions, the same command sequence causes the gate
Off
to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
during opening, cutting photocell stops the gate until the obstacle is
On
removed. When the obstacle is removed the gate resumes opening;
Off
during opening, the photocell does not cut in.
NO-REVERSE function activated; the gate ignores the closure commands
On
during opening; reversal of movement occurs only during closure;
the open-close pushbutton reverses the direction of movement of the
Off
gate even while it is opening.
On
pre-flashing function enabled.
Off
pre-flashing function disabled.
On
"photocell test" function is enabled;
"photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
Gate contact open: The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deactivates
once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to activate
and remain active until the subsequent impulse.
Monostable function active for 2 sec.: the radio control impulse causes the
contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes the
contact to activate and remain active for 180 sec.
On
setting for heavy gates
Off
setting for standard gates
On
left-hand leaf opening function;
Off
right-hand leaf opening function;
ENCODER enabled: encoder obstacle detection function activated (use
On
the trimmers FR and SENS to adjust the sensitivity to obstacles);
Off
ENCODER disabled - obstacle detection disabled;
On
RESISTIVE SENSITIVE EDGE (terminal no. 11);
Off
FIXED EDGE (NC contact – terminal no. 11).
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S-350k580m

Tabla de contenido