4.
TESTING THE AUTOMATIC SYSTEM WITH EL16 ELECTRONIC BOARD
GB
4.1 Checking the dip-switches
DIP1 = OFF for REX2 and REX1-DX
DIP1 = ON for REX1-SX
DIP2 = ON for REX
DIP1 = ON
DIP2 = OFF
DIP3 = OFF for REX
4.2 Functional test
Wire up as shown in fig. 3, close the contacts 41-6, 41-8, 1-9.
Connect the transformer to mains (230 V~/50 Hz).
Give the following commands to the electric board and visually check for correct response and straight and smooth running.
Electric board turned on
Command 1-3A and OPEN button (impulsive)
Command 1-4 (impulsive)
Command 27-3B (impulsive) and RP trimmer at minimum
Close contacts 1-2
Command 41-6 during opening (opening contact)
Command 41-8 during closure (contact open)
Control of the photocell card during the closure phase:
- connect the CelPR
Command 1-9 (contact open)
Command 1-29 and RESET button (impulsive)
4.3 Chaos test
Send repeated open and close commands so as to cause the wing or wings to continuously reverse direction of movement without
stopping (for at least 1 minute). Check that the automation system does not fail to appropriately keep wing position under control
nor cause the wing or wings to slam, and that no logic malfunction occurs.
4.4 Checking the trimmers
TC trimmer adjustment
R1 trimmer adjustment
RF trimmer adjustment
VA trimmer adjustment
VC trimmer adjustment
RP trimmer adjustment
4.5 Default setting
Set the following configurations at the end of the test:
-
all trimmers at minimum;
-
DIP1 is dependent on the type of automation; DIP2=ON;
-
all DIR dip-switches in the OFF position;
-
disconnect batteries (if installed), checking that the electric board is not being powered by them (press RESET command).
4.6 General controls
-
Control the length of the casing, the passage width and the width of the leaf.
-
Tie the power supply cable and command cables with related channels.
-
Apply the casing seal.
-
Perform a general check (belt tension, screw tightness, etc).
-
Fill-in and apply the CE label.
KIT REX - IP1837
ACTION
ACTION
ACTION
- changing the opening direction
- automation type selection
Warning: DIP2 must be set to ON
- battery function, if present, in the event of blackout
- in the event of blackout, the automation with the batteries pre-
sent performs the last opening manoeuvre and then switches
off
- block type selection
Warning: DIP3 must be set to OFF
- green LED lit
- closure manoeuvre
- opening manoeuvre
- partial opening manoeuvre
- re-opening
- reduce in the last 500 mm of the door stroke when the con-
tact is opened.
- the gate should open when the optical alignment between TX
and RX is broken.
- stop for the duration of the command
- reset, encoder zero setting
- reset, encoder data reset
- variation of the automatic closure time
- variation of the force on obstacles
- variation of the motor power
- variation of the opening speed
- variation of the closing speed
- variation of the partial opening