Refrigerant System - Scotsman MF 58 Split Manual De Servicio

Fabricadores modulares de hielo supertriturado
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REFRIGERANT SYSTEM

WARNING - MF 58-68 can NOT be connected to a
sub-cooled liquid refrigerant system.
The refrigerant system of the new MF 58-68 Flakers
Split versions consists off:
1
Refrigerant inlet flared male connection (3/8")
2
Refrigerant outlet flared male connection
(1/2" MF 58 and 5/8" MF 68)
3
Liquid solenoid valve
4
Thermostatic expansion valve (Flica TMVX ø
2.0 mm - 2 pcs on MF 68)
5
Refrigerant evaporating pressure regulating
valve (Danfoss KVP 12 on MF 58 and
Danfoss KVP 22 on MF 68)
The refrigerant system is supplied completely sealed
with two copper caps located on the flared nuts and
pre-charged with a limited quantity of R404a.
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mf 68 split

Tabla de contenido