Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
GB
4
Fit the adaptor at
the back edge of
the rail.
7
Use suitable lifting
equipment to lift the
trolley (with balancer,
90°-elbow and vertical
hose). Roll the trolley
in to the guide track.
Connect the horizontal
hose.
10
Connect 110/220 V AC to the connection
box fitted on the back edge of the rail.
16
MagnaTrack LL
M8 x 12
6
Suspend the hose by threading the
carriers into the guide track. Make
sure the carriers are correctly fitted
according to the figure to the right.
Also check that they are free run-
ning so they do not snag in the guide
rail joints.
Connect the cable to the
disconnection box.
5
Fit the
connection box.
Fit the disconnection magnet on the
front part of the guide track and on the
same side as the disconnection box
on the trolley. The exact distance of
the disconnection magnet from the
front edge of the guide track must
be checked according to the
installation checklist,
see page 19.
9
Connect the cable to
the connection box.
8
Fit the fixing plate with
the shock absorber in
the front edge of the rail.

Publicidad