Nederman MagnaTrack LL Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
1
Fasten the
mounting chains,
approximately 2,4 m
(8 ft) apart, in every other
profile.
The first mounting bracket should be braced
with a reverse angled bracing bar.
4500 N
1010 lbs
F
0.1 - 1.0 m
4 in - 3 ft
3
Lift the whole rail and fit it in the ceiling.
The mounting chains should be fixed in
bars, brackets or similar arrangements
according to the examples below.
All mounting brackets should
be braced with two bracing bars
positioned sideways according to
one of the figures.
MagnaTrack LL
~ 2.4 m
~ 8 ft
2
Place all the rail profiles in line with
each other on the floor, as shown in the
figure. Screw the profiles together with
the lengthening joints.
The last mounting bracket should be braced
with a forward angled bracing bar.
4500 N
1010 lbs
F
The entire guide rail can be mounted
with a slight fall: 50 - 100 mm (2 - 4 in)
is recommended per 6 m (20 ft) length
(the lowest point to be at the station
door end of the track).
When mounting the rail, ensure that sui-
table fixing bolts are used considering
the ceiling construction material and the
traction forces in the suspension points.
GB
4500 N
1010 lbs
F
15

Publicidad

Tabla de contenido
loading

Tabla de contenido