Displays; Alarms - Dal Zotto INSERTO IDRO 800 Manual Del Usuario

Tabla de contenido

Publicidad

DISPLAY
OFF
Generator o
START
The start-up phase is in progress
PELLET FEEDING
Continuous pellet feeding is in progress during the ignition phase
IGNITION
The ignition phase is in progress
PREPARATION
The preparation phase is in progress
WORK
The normal work phase is in progress
MODULATION
The generator is working at minimum
FINAL CLEANING
The nal cleaning is in progress
STAND BY
Generator o waiting for re-ignition due to an external thermostat
A new ignition is attempted when the generator has just been switched o . When the generator switches o , one must wait for
WAITING
the complete shutdown of the fumes motor, then clean the burn pot. The generator can only be re-ignited when these operations
COOLING WAIT
have been performed.
HOFF
Generator o due to water temperature over set
*T AMB
Display the ambient temperature (in models with this function)
*T OFF
Generator o waiting for re-ignition due to all requests met
WAITING
The generator is cooling after a power cut.
BLACK OUT
Once cooling is completed it will re-start automatically
The anti-freeze function is in progress as the H2O t is below the factory set threshold
ANTI FREEZING
the pump is active until the water reaches the pre-set factory parameter +2°C
The pump antilock function is in progress (only if the generator has been in an OFF state for at least 96 hours); the pump is
ANTI BLOCK
activated for the time pre-set by the manufacturer, in order to prevent it from blocking
BLOW
The automatic blow is active
HE CLEAN BLOCK
The automatic cleaning of the springs has stopped abnormally: motor blocked/damaged
DISPLAY
Indicates the presence of an alarm.
ASPIRATOR
Fumes motor fault
FAULT
FUMES PROBE
Fumes probe failure.
HOT FUMES
High exhaust temperature
The pellet feed-box is empty.
NO
Pellet feed calibration inadequate.
IGNITION
Thermostat bulbs tripped
BLACK OUT NO IGNITION
No current during the ignition phase.
BLACK OUT
* on models with this function.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM
74

DISPLAYS

ALARMS

EXPLANATION
ENGLISH
REASON
On: indicates the presence of an alarm.
Flashing: indicates the deactivation of the depression sensor
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/
Contact after-sales centre
Contact after-sales centre
Check pellet feed (see "Pellet feed adjustment"). If the problem cannot be
solved, contact an authorised technician.
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Check the thermostats with bulbs (see chapter on resetting)
Take the stove to OFFconditions using key 1 and repeat the procedure
described in the "Ignition" chapter.
SOLUTION
for 3 seconds.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Natura e calore

Tabla de contenido