- The panel deactivates itself from the Master mode following the same activation procedure: 3 quick
presses of the SW1 button. A deactivation tone sounds (beep-bop). It can also be deactivated with a
keypad code, without having to open the panel, see»Configuring the Direct Panel» for more details.
The sequence is: Deactivate the panel as MASTER: 10 (beep) 0 (beep-beep).
- 2 simultaneous conversation channels on the same pair..
Lock-release code change.
You can change the lock-release code from the keypad at anytime (if enabled) without
needing to enter in configuration. It´s useful if you want to allow the residents this change.
The procedure to change it is the following:
A + 3141 + Current code (4 digits) + New Code (4 digits)
If the code is correct, a confirmation tone sounds (beep-beep) and if not the error tone
sounds (beep-bop). In this case you can´t enter a digit with the value "A" as a "New Code»..
Auto-Start.
If the phone is not programmed, the auto-start will not function.
This function is possible with the panel in the same block; if the panel is in standby and
programmed as «0»; and if there is a conversation channel available.
If you do not want this function just change the outdoor panel number to something other
than 0.
Section II - Manuel de Programmation
Pag 47