Zone 1 Entry/Exit Delay
Zonea1 has a delay (default 30 seconds, configurable) that allows the user a minimum time to arm or
disarm the alarm zones when entering or leaving the house, without any of the alarms going off.
The delay can be set between 00 and 99 seconds.
ACTION
PROGRAM ZONE 1 E/E DELAY
Configuration of 24-Hour Zones
It is possible to define alarm Zones 3 and 4 (terminals A3,A3 and A4, A4 of the connections module,
respectively) as «24-Hour Zones».
Zones configured as «24 Hours» set off the alarm every time the sensors are activated, if the zone is
enabled, whether the system is armed or disarmed.
Alarm zones configured as 24 hours are usually those destined to detection of smoke, gas and water leaks,
etc..., i. e. the zones you want to generate alarms at all times, even when the user is at home.
ACTION
ZONE 3 NORMAL MODE
ZONE 3 24 HOUR MODE
ZONE 4 NORMAL MODE
ZONE 4 24 HOUR MODE
Change Master Code
For enhanced security, it is advisable to change the initial Master Code (1234) for another personal and private
one. In this way, only those users who know the new Master Code will be able to access the monitor functions.
ACTION
CHANGE MASTER CODE
Forgotten Master Code.
If you forget the Master Code, the sequence to follow is as follows:
1- Unplug the telephone power supply. Pick up the handset.
2- Reconnect the power supply, keeping the thre buttons pressed simultaneously. The telephone emits a long
beep, and, in instalaciones MDS-Digital installations with Guard Unit, sends a Tamper alert to the guard unit, to
prevent fraudulent manipulation.
3- The new Master Code is "1234". It is advisable to change it for another one immediately.
Pag 28
KEY SEQUENCE
Master Code + AB + 9 + Timing (00..99)
KEY SEQUENCE
Master Code + AB + A + 0
Master Code + AB + A + 1
Master Code + AB + B + 0
Master Code + AB + B + 1
KEY SEQUENCE
Current Master Code + AB + 0 + New Master Code
EXAMPLE
1234AB945
Zone 1 delay 45 sec
EXAMPLE
1234ABA0
1234ABA1
1234ABB0
1234ABB1
EXAMPLE
1234AB04321