General data
Dimensions (width x height x depth)
Weight
Storage conditions
Relative humidity
Protection class according to EN 60529/IEC529
Supply voltage
Permissible ripple
Mounting orientation
Fuse for voltage: external valves
Fuse for voltage: external electronics
Notice: maximum current in the 0 V line
Internal voltage drop
Current requirement for electronics
Power supply for initiators
Power supply for valves
Start-up time after switching
on the supply voltage
Temperature range
Storage temperature
AVENTICS | SERCOS III | R412012613–BDL–001–AC

12 Technical data

50 mm x 120.5 mm x 106.5 mm
Approx. 425 g
< 80 % RH
0 – 95 %
IP 65 (only when assembled and with all plugs
mounted and electrical connectors closed)
24 V DC sensor voltage (±20 %)
24 V DC valve voltage (±10 %)
For the supply voltage, only use a power pack with
safe isolation.
5 %
Any
3 A T
3 A T
Max. 4 A
0.8 V
90 mA
Max. 3 A per DDL line
Max. 3 A per DDL line
2 s
+5 °C to +50 °C
-20 °C to +70 °C