Software Addressing (Variant 2); Sercos Iii Process Data And Structure Elements; Bus Coupler; Ddl Participants - Aventics DDL Instrucciones De Servicio

Sercos iii
Ocultar thumbs Ver también para DDL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 145
Table 10:
SERCOS III function groups
I/O function group
S-0-1502.x
Digital output
S-0-1503.x
Digital input
S-0-1504.x
Analog output
S-0-1505.x
Analog input
AVENTICS | SERCOS III | R412012613–BDL–001–AC
13.2.2

Software addressing (variant 2)

As an alternative, it is possible to let the master assign the
SERCOS III address in accordance with the SERCOS III
specification.
13.3 SERCOS III process data and structure
elements
13.3.1

Bus coupler

The bus coupler provides all necessary structure elements
according to the SERCOS III specification "SCP_FixCFG".
The function groups are available, for example, through the
IDN/S-0-1302.0.2. The assignment to the DDL participants can
be found here:
13.3.2

DDL participants

The DDL participants are divided into the following function
groups:
DDL slave
Digital output module
Valve unit without inputs
Combination module (valve unit with inputs, digital I/O module,
analog module), output side
Digital input module
Combination module (valve unit with inputs, digital I/O module,
analog module), input side
EP pressure regulator set point
EP pressure regulator actual value