SET dT ALLOWED
This option can be used to define the maximum limit of the allowed temperature difference (between 1°C and
10°C) between the ceiling area and the floor area. In the Winter Automatic operating mode, the control unit
switches the fans on at the maximum set speed when this limit is exceeded by 3°C and, as the temperature
difference decreases, it adjusts the speed until the fans switch off when the difference goes back below the
defined limit.
SET dT
ALLOWED
SET FLOOR MIN
This option can be used to define the minimum temperature limit measured at the floor level, below which the
control unit switches on the heating system that may be connected. The temperature can be set within a range
from 10°C to 15°C.
SET FLOOR MIN
RELAY OUT TYPE
This option can be used to define if the relay that controls the heating system is normally open (NO) or normally
closed (NC).
RELAY OUT TYPE