Important
The connection must be made by authorised,
skilled personnel, in accordance with the rele-
vant legal requirements, using appropriate and
specifi ed materials.
The appliance is supplied with operating volt-
age 400V/3~N (230V/3 available on request)
(see attached wiring diagrams).
Specify the correct voltage for your device; it
cannot be modifi ed after purchase.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
If not already present, install an automatic
1)
circuit-breaker
, close to the appliance, with
(A)
the following characteristics:
– Thermal breaker device (to adjust see table
Annexes).
3320040_inst_GB_rev.1
ELECTRICAL CONNECTION
B
C
D
– Magnetic circuit breaker curve B (IEC 60898-
1).
– Residual current protection set at mA 30.
Open the hatch (B).
2)
Undo the screws to remove the drain lever
3)
(C).
Undo the screws to remove the panel
4)
Undo the screws to remove the guard (E).
5)
Connect the circuit-breaker (A) to the terminal
6)
board (F) of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual and using a cable
with the following characteristics.
– Weight: ≥ than H05RN-F type (designation
245 IEC 57).
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Replace all when the operation is complete.
7)
E
- 11 -
.
(D)