5) PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Motor 1 work time. Regulates the maximum duration of the opening and closing manoeuvre
TM1
of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Motor 2 work time. Regulates the maximum duration of the opening and closing manoeuvre
TM2
of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
Torque of Motor 1. The torque applied to motor 1 is adjusted.
COMPLY WITH REGULATIONS IN FORCE!
PM1
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
Torque, Motor 2. The torque applied to motor 2 is adjusted.
COMPLY WITH REGULATIONS IN FORCE!
PM2
In oil-hydraulic motors, regulate unit to maximum value (99).
Use the by-pass valves to adjust the applied torque.
The torque applied to motor 1 during braking in the opening and closing phase is adjusted.
PS1
COMPLY WITH REGULATIONS IN FORCE
The torque applied to motor 2 during braking in the opening and closing phase is adjusted.
PS2
COMPLY WITH REGULATIONS IN FORCE!
ELS/SRL contact activation time.
At the beginning of each single operation, the contact closes for the preset time.
TLS
If it is preset on 0, it has the service light function. The contact remains closed when the motor
is moving or is in TCA dwell time and it opens when the motor is stopped.
MENU
Enables or disables automatic closing
TCA
On: automatic closing enabled
Off: automatic closing disabled
Enables or disables condominium function.
Off: condominium function disabled.
IbL
On: condominium function enabled. The step-by-step impulse or transmitter impulse has no
effect during the opening phase.
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention of the
SCL
photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
Braking is enabled or disabled.
On: Braking activated. Braking starts around 7 seconds before the end of the operating time
Sld
preset with TM1/TM2 parameters.
Off: Braking excluded.
Selects the operating mode of the "Step by step button" and of the transmitter.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Enables or disables pre-blinking.
PRE
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
The reversion function is enabled or disabled.
On: Enabled function. Before every opening operations, the control unit control a 2sec
HAM
operation in the opposite direction to facilitate the release of the electric lock.
Off: Disabled function.
14
5.1) PARAMETERS (PAR)
FUNCTION
5.2) LOGIC (LOG)
FUNCTION
MIN-MAX-(Default)
MEMO
1-240-(40s)
5-180-(24s)
5-180-(24s)
0-15-(2s)
0-40-(3s)
1-99-(40%)
1-99-(40%)
1-99-(70%)
1-99-(70%)
0-240-(90s)
ON-OFF-(Default)
MEMO
(ON)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)