About Error Codes - Sony VPH-G70Q Manual De Instalación

Ocultar thumbs Ver también para VPH-G70Q:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

About Error Codes

List of the Projection Distance by Angle of Optical Axis
When a critical operational error
occurs, the power will be
automatically turned off and the error
code will light up on the error code
window inside the projector. You can
check the code without removing the
cover. Refer to the chart below for the
meanings.
Error code
Item
10
20
Unknown
21
POW1 (115HV)
22
POW2 (115DEF)
23
POW3 (50)
24
POW4 (15)
25
IFB
26
LENS
27
POLARITY
29
B
30
DC
31
EB
32
EC
33
HV
34
LOT
35
H.STOP
36
V.STOP
37
FAN
38
CRT
39
Ik
∑ Ik
40
88
CPU RESET
Notes
• When the error code lights up, the previous adjustment data may be cleared.
• The error code disappears when the MAIN POWER switch is turned off and the power cord is disconnected.
• The error code lights up every time the power is turned on until the critical operational error is returned to normal.
• Immediately after the MAIN POWER switch is turned on, "88" is displayed for about one second. This is not a problem.
The unit resets the CPUs to the initial status during this period.
112
(EN)
Others
Meaning
Abnormal input signal. Check the input signal.
Abnormalities that do not come under the errors below.
Abnormal in the 115 V (HV) line
Abnormal in the 115 V line
Abnormal in the 50 V line
Abnormal in the 15 V line
Abnormality of the interface board installed to the INPUT B section
A lens is removed.
The connector cover for polarity change does not shut completely.
Abnormality of the power line on the B board
Abnormality of the power line on the DC board
Abnormality of the power line on the EB board
Abnormality of the power line on the EC board
Abnormal high voltage
Abnormal load on a LOT of the PA board
Horizontal polarity is not correct.
Vertical polarity is not correct.
A fan inside the projector does not work.
Current in any of the R, G and B CRTs exceeds the rated output (detectable on the C board).
Current in any of the R, G and B CRTs exceeds the rated output (detectable on the B board).
There is abnormality in the CRTs.
The CPUs on the YA, YB and YC boards are reset.