Accessories And Consumables; Problem Solving - Wetrok iMatic XR85 Instrucciones De Manejo Abreviadas

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Power Shot
PShot
Pressing the power shot
button causes water quan-
tity, brush pressure and
suction to run at full power
for 6 seconds for local
areas of heavy soiling.

Accessories and consumables

Pad-drive disk

Problem solving

FAULT
Machine does not work
Cleaning action inadequate
No suction or suction inadequate
Streak formation
No supply of cleaning agent or water, or supply
inadequate
Laser not functioning or poorly visible
Batteries not charged or charge is too low
Long Running System (LRS):
LRS
Pressing the LRS button causes water
quantity, brush pressure and suction to be
reduced to economy operation. This mode
is recommended for cleaning smooth and
slightly soiled floors. This saves water
and cleaning agent and at the same time
increases service time.
Polypads
CAUSE
Emergency stop button pressed
Fuse or overvoltage protection tripped
Machine switched off automatically
Power down function)
Magnetic brake does not disengage
Brush / pad badly worn
Dosing / water too low
Suction nozzle or suction hose clogged
Suction hose not connected
Tank lid not closed or seal defective
Sealing lid at outlet hose not correctly screwed on or
seal faulty
Turbine switched off or at reduced level
Suction lips contaminated or worn
Suction nozzle pad incorrectly adjusted
Tubes clogged
Fresh water filter clogged
Water supply closed
Chemicals supply closed
No fresh water in tank (Water pump operation audible)
Laser lens is soiled
Laser is incorrectly adjusted
Unsuitable conditions of floor or lighting
Duration of battery charging too short
End of battery service life reached
27
Scrubbing brush
Supernylon
SOLUTION
Unlock emergency stop button
Carry out reset with key switch OFF/ON
Carry out reset with key switch OFF/ON
Check main controller plug
Replace brush / pad
Increase dosing / water
Remove clogging
Connect suction hose
Close tank lid correctly or replace seal
Check seal, screw on lid firmly, replace if necessary
Switch on turbine or increase to full suction power
Clean or replace suction lips
Correctly adjust height and angle of suction nozzle
(should be done by specialist)
Rinse fresh water tank and tube system with clean
water
Clean fresh water filter
Open or adjust water supply
Open chemicals supply and/or restart dosing
Fill with fresh water
Clean carefully with cleaning cloth
Readjust laser attachment
(should be done by specialists)
---------------------
Observe the required charging duration
Change batteries (observe safety instructions)
Drive-assistant laser
When appliance is moved forwards the
integrated laser system automatically
projects a 1-metre line to the right in
front of the brush housing. This makes
drive positioning of the machine easy,
thereby avoiding cleaning the same
spot twice (no overlapping of cleaning
tracks).
Scrubbing brush
Tynex (very hard)
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido