Using the machine
Inserting needles
- Switch the machine off " O ".
Disconnect machine from
electricity supply.
- Turn the handwheel until needles
are fully raised.
- Lower the presser foot.
- Use the hexagon wrench to loosen
the needle setscrew.
Remove needle.
- Insert the needle flat side towards
the back, as far as possible into the
needle clamp.
Tighten the screw.
- The left needle is set higher than
the right needle.
Raising the upper knife
- Turn the handwheel to raise the
needles.
- Open the looper cover.
- Press the upper knife holder to
the right. Turn the knob clockwise
until the knife engages.
- Close the looper cover.