11 FUNCTION TEST

After all repair work, the spray gun must be checked for safe condition before recommissioning.
The necessary scope of inspection and testing depends on the repair carried out and must
be documented by the repair personnel.
Assembly inspection
Activity
1. Leak test
– Connect 1 bar; 0.1 MPa; 14.50 psi air pressure to the air connection and
product connection.
Place the spray gun completely into the water bath and check all sealing
points with 4 bar; 0.4 MPa; 58 psi for leaks.
At 4 bar; 0.4 MPa; 58 psi, a slight leak can be tolerated.
Injection and Final Inspection
Activity
2. Trigger lever function test
– The trigger lever must be pulled as far as it will go.
Make sure that the trigger lever can move slightly in its rest position.
3. Leak test
– Connect the spray gun, slowly increase the product pressure in increments
using a suitable medium until the maximum pressure (8 bar, 0.8 MPa; 116 psi)
specified on the spray gun is reached.
– Trigger and flush the spray gun multiple times.
– Check the following:
– Is the product connection sealed when the gun is closed?
– Is the product valve sealed?
– Is there no product discharge at the valve rod seal?
If product leaks, tighten clamping sleeve:
Clamping sleeve of the needle packing on the valve rod must be tightened.
If necessary, tighten the clamping sleeve with the wrench.
(In doing so, it is important to make sure that the valve rod still runs smoothly
and the gun closes reliably).
Activity
4. Checking the switching sequence
– Mount nozzle and air cap nut.
– Set the injection pressure to 8 bar; 0.8 MPa; 116 psi, pull the trigger slowly,
note the switching sequence "Switch on" and "Switch off".
Switch on: shaping air on, product on
Switch off: product off, shaping air off
5. Flush the spray gun
– Switch off the air and product supply, pull trigger lever and flush spray gun or
blow out with air.
Flush the gun without the valve and air cap.
In doing so, you can remove the air connection hose.
– When almost no more product comes out, remove the product connection
hose and blow the rest of the test medium out of the spray gun using an
air gun.
DOC2422648
PILOT GM 1030P
Means
Air connection, 1 bar
Water bath
Means
Manual inspection
Visual inspection
Product connection, 8 bar
Air connection, 3 bar
Size 7 mm wrench for the
clamping sleeve
Means