Gráfico de tiempo de arranque de antorcha
Start signal (torch trigger) ON/OFF
(control board Start LED ON/OFF)
Internal compressor ON/OFF
Pilot arc IGBT ON/OFF
Gas solenoid ON/OFF
Inverter output ON/OFF
Control board Transfer LED ON/OFF
(system is cutting)
Powermax30 AIR Manual de servicio 808853
Compressor
Gas
pressurizes
solenoid opens
Idle
(350 ms)
(15 ms)
Inverter on
Transfer
until pilot arc
(when work lead
Cutting
established
current > 0.4 A)
(steady state)
Pilot arc current = 15 A
Transfer threshold: 1.6 A
9 – Diagramas eléctricos
Torch
trigger released
Idle
Postflow
(5–20 seconds)
Postflow
(5–20 seconds)
User-set current
221