Parker ATT Serie Manual De Uso página 251

Ocultar thumbs Ver también para ATT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
42
AIR FILTER
40
BP2
AIR PRESSURE SENSOR COLUMN 2
39
BP1
AIR PRESSURE SENSOR COLUMN 1
38
FLOWMETER
36
AIR PRESSURE MANOMETER
35
BY PASS VALVE
34
YV1
LIQUID LINE SOLENOID VALVE
33
SILENCER
32
YV2
HOT GAS SOLENOID VALVE
YPD
31
ETV DISCHARGE COLUMN
30
OIL FILTER
29
POWDER FILTER
28
AIR OUTLET VALVE
BT1
27
DEW POINT
25
ELECTRICAL HEATER
24
PS2
LOW PRESSURE SWITCH 2
23
PS1
LOW PRESSURE SWITCH 1
22
AIR PRESSURE MANOMETERS
21
AIR FILTER
20
VESSEL 2
19
VESSEL 1
18
AIR PURGE VALVE
17
AIR INLET VALVE
16
PRESSURE CONNECTION
15
CONDENSATE DRAIN VALVE
14
CONDENSATE FILTER VALVE
13
CONDENSATE DRAIN SOLENOID VALVE
YVD
12
LP
LOW PRESSURE SWITCH
11
HP
HIGH PRESSURE SWITCH
10
PV
WATER PRESSURE VALVE
9
AIR-AIR HEAT-EXCHENGER
8
HOT GAS VALVE
7
REFRIGERANT FILTER
EXPANSION CAPILLARY
6
5
SEPARATOR
4
EVAPORATOR
3
SHUT-OFF VALVE
2
REFRIGERANT CONDENSER
1
COMPRESSOR
Pos.
Ref.
DESCRIPTION
REFRIGERANT CIRCUIT 140 (Wc)
FILTRO ARIA
SENSORE DI PRESSIONE ARIA COLOMNNA 2
SENSORE DI PRESSIONE ARIA COLOMNNA 1
FLUSSIMETRO
MANOMETRO PRESSIONE ARIA
ELETTROVALVOLA DI BY PASS
ELETTROVALVOLA LINEA DI LIQUIDO
SILENZIATORE
ELETTROVALVOLA GAS CALDO
ELETTROVALVOLA SCARICO COLONNA
FILTRO OLIO
FILTRO POLVERE
VALVOLE USCITA ARIA
PUNTO DI RUGIADA
RESISTENZA RISCALDANTE
PRESSOSTATO BASSA PRESSIONE 2
PRESSOSTATO BASSA PRESSIONE 1
MANOMETRI PRESSIONE ARIA
FILTRO ARIA
VESSEL 2
VESSEL 1
VALVOLE PURGA ARIA
VALVOLE D'INGRESSO ARIA
PRESA DI PRESSIONE
RUBINETTO SCARICO CONDENSA
FILTRO SCARICO CONDENSA
ELETTROVALVOLA SCARICO CONDENSA
PRESSOSTATO BASSA PRESSIONE
PRESSOSTATO ALTA PRESSIONE
VALVOLA PRESSOSTATICA ACQUA
PI1
SCAMBIATORE ARIA-ARIA
YBP
VALVOLA GAS CALDO
SQ1
FILTRO REFRIGERANTE
B10
CAPILLARE ESPANSIONE
B9
SEPARATORE
B5
EVAPORATORE
B4
VALVOLA DI INTERCETTAZIONE
B3
CONDENSATORE REFRIGERANTE
B2
COMPRESSORE
DENOMINAZIONE
ATT140-340
FULL PROTECTION HEATER
BY PASS ALLARM
CONDENSATE LEVEL SENSOR
THERMAL MASS TEMPERATURE SENSOR
ABSORBER AIR INLET TEMPERATURE SENSOR
HEATER AIR OUTLET TEMPERATURE SENSOR 2
HEATER AIR OUTLET TEMPERATURE SENSOR 1
COMPRESSOR DISCHARGE TEMPERATURE
PURGE AIR TEMPERATURE SENSOR
Ref.
DESCRIPTION
PROTEZIONE INTEGRALE RESISTENZA
ALLARME BY PASS
SENSORE DI LIVELLO DI CONDENSA
SONDA TEMPERATURA MASSA TERMICA
SONDA TEMPERATURA ARIA INGRESSO ABSORBER
SONDA TEMPERATURA USCITA ARIA DALLA RESISTENZA 2
SONDA TEMPERATURA USCITA ARIA DALLA RESISTENZA 1
TEMPERATURA SCARICO COMPRESSORE
SONDA TEMPERATURA ARIA DI PURGA
DENOMINAZIONE
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Att140Att260Att340

Tabla de contenido