Dismantling And Repairs - Festo CLR-12 Instrucciones De Utilizacion

Ocultar thumbs Ver también para CLR-12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
CLR−...
8
Operation
Warning
Uncontrolled moving masses can cause injury to people or damage to objects in
the area of movement (squashed fingers, eye injuries).
S Make sure that nobody can place his/her hand in the positioning range of the
moveable mass (e.g. by means of a protective screen). It must not be
possible to touch the CLR−... until the mass has come to a complete stand.
Make sure that the swivel frequencies in continuous operation do not exceed
S
the specified values (see chapter Technical specifications").
9
Care and maintenance
Cleaning:
If necessary, clean the exterior of the CLR−... with a soft cloth.
S
The following cleaning agents are permitted:
soap suds (max. +60 °C)
petroleum ether
any non−abrasive media.
10

Dismantling and repairs

For all dismantling and repair work:
Exhaust the CLR−...
S
Removing the clamping finger
1. Fix the piston rod at spanner flat 6 with a
spanner wrench (note the maximum per
mitted torque on the guide sleeve, see
chapter Mechanical installation").
2. Unscrew the fastening screw one turn out
of the clamping finger.
Festo CLR−... 0604c English
Fig. 24
31

Publicidad

Tabla de contenido
loading