Names and Operations of Parts
Camera unit
View when the dome cover is removed.
1
Camera Head
For adjusting the angle of the camera,
such as during focusing, etc.
(
page 14)
2
[IRIS LEVEL] sensitivity adjustment
volume
For adjusting the iris level of the lens.
By turning this volume, the brightness of
video signals can be adjusted.
To darken image Counterclockwise (L side)
To brighten image Clockwise (H side)
MEMO
• When turning the level (sensitivity
adjustment) too far to the L side, the
sensitivity will increase by the AGC of
the camera and the picture quality will
reduce. For this reason, always set the
AGC switch to "OFF" when making
LEVEL adjustments.
E-6
Turning direction of level
3
MONITOR terminal (RCA pin)
For connecting a monitor when determin-
ing camera angle, etc. (High impedance)
4
Horizontal lock screw
When adjusting the camera angles of
horizontal rotation, this screw is loosened
for adjustment and tightened to maintain
the angle.
(
page 14)
5
Tilt lock screws
During adjustment of the vertical image
pickup direction of the camera angle,
loosen the screws (2 locations) and
retighten after performing adjustment.
(
page 14)
[FOCUS ADJ. - ON/OFF] focus
6
adjustment switch
When adjusting the focus during
installation, setting this switch to "ON" will
open the iris.
(Default setting: OFF)
(
page 14)