Message table (continued)
Indicators
The POWER indicator, LAMP indicator and TEMP indicator light or blink in the following cases.
POWER
LAMP
indicator
indicator
Lights orange
Turns off
Flashes green
Turns off
Lights green
Turns off
Flashes orange
Turns off
Lights red
Lights red
Flashes red
Lights red
Turns off
Lights red
Flashes red
Flashes red
When the LAMP or TEMP indicator lights or flashes, turn off the MAIN POWER switch before proceeding. If the problem still persists, contact your
dealer or service company.
*1: When the cooling fan is stopped and the interior becomes overheated, the power will turn off automatically to allow cooling (the indicator will turn
off). In such cases, turn off the projector power, allow the set to cool and then turn the projector power on again. The lamp will then light. If the lamp
does not light, contact your dealer or service company.
*2: In some cases, when the air holes becomes blocked and the interior temperature rises, the lamp will be turned off for protection and the LAMP
indicator will flash red. In such cases, turn off the MAIN POWER switch, allow the set to cool (for approx. 20 min.) and then turn the power on again.
When you think something wrong
Before requesting repair, check in accordance with the following chart. If the situation cannot be corrected, then
contact your dealer.
Symptom
The power is not
•The main power switch is not turned on.
turned on.
•The power cord is disconnected.
No video or audio.
•The input is not correctly set.
•No signal input.
Video is present but
•The projector is not correctly connected.
no audio.
•The volume is set to minimum.
•Mute is turned on.
•Audio is switched to RGB when P in P is on.
Audio is present but
•The projector is not correctly connected.
no video.
•The brightness adjustment knob is rotated
fully clockwise.
•The lens cap is still on.
Color density and color matching are not
Colors are pale and
color matching is poor.
correctly adjusted.
Images are dark.
•Brightness and contrast are not correctly adjusted.
•The lamp is nearing the end of its service life.
Video is blurred.
Focus or H PHASE is out of adjustment.
Lamp failure.
The LAMP indicator
lights red.
Internal overheating.
A bright dot may be seen in the picture. This is a phenomenon peculiar to the liquid crystal and is not a problem.
TEMP
indicator
Turns off
Standby status
Turns off
Warming up
Turns off
Operation status * 1
Turns off
Cool down
The lamp does not light. * 2
Turns off
The interior is too hot.
A lamp has not been inserted
Turns off
or the lamp cover is missing.
Flashes red
The cooling fan is not operating.
The total lamp time has
Turns off
exceeded the replacement time.
Possible cause
Status
Wait some time (approx. 20 min.) before
turning the power on again. Clean the air
filter before turning the power on. If the
indicator still lights, contact your dealer.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Remedy
•Turn on the main power switch.
•Plug the power cord into an AC power outlet.
•Use the projector or remote control to set.
•Connect correctly.
•Connect correctly.
•Press VOLUME + on the remote control or display
the menu screen and adjust the volume.
•Press the MUTE button.
•Displays the Volume bar and switches the Audio input.
•Connect correctly.
•Select BRIGHT with the MENU button and then
press the (
) key.
•Remove the lens cap.
Adjust the video.
•Adjust the video.
•Replace with a new lamp.
Adjust the focus or H PHASE.
Wait approximately 20 min. and then turn the
power on again.
•Make sure the ventilation openings are not blocked.
•Clean the air filter.
•Lower the ambient temperature to 35 degrees C or less.
Processing
Page
P.13
P.9
P.8,10,
13,19
P.9,31
P.9,31
P.10,18
P.8,10
P.10
P.9,31
P.17
P.13
P.18
P.18
P.32
P.13,18
P.33
P.31,32