Operating The Rotating Laser; Preparations At The Workplace; Switching The Laser On And Working In The Horizontal Plane - Hilti PR 30-HVS A12 Manual De Instrucciones

Ocultar thumbs Ver también para PR 30-HVS A12:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Drop test height in the PRA 30 laser receiver holder
(under standard ambient conditions in accordance with
MIL­STD­810G)
Operating temperature
Storage temperature
Weight (including batteries)
Protection class in accordance with IEC 60529 (except
battery compartment)
5

Operating the rotating laser

5.1

Preparations at the workplace

CAUTION
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.2
Handling the laser and battery correctly
The B12 battery has no protection class. Do not expose the battery to rain or wet conditions.
In accordance with the Hilti instructions, the battery may be used only with the associated product
and must be inserted in the battery compartment for this purpose.
1. Fig. 1: Working in horizontal mode.
2. Fig. 2: In inclined plane mode, the laser should be lifted at the control panel side.
3. Fig. 3: Laying down or transporting in an inclined position. Working in the vertical plane.
◁ Hold the laser so that the battery compartment does NOT face upwards, so that no moisture can
enter.
5.3
Inserting / removing the battery
CAUTION
Electrical hazard. Dirty contacts may cause a short circuit.
▶ Check that the contacts on the battery and on the tool are free from foreign objects before inserting the
battery.
CAUTION
Risk of injury. If the battery is not fitted correctly it may drop out and fall.
▶ Check that the battery is securely seated in the tool so that it cannot drop out and fall, thereby presenting
a hazard to other persons.
1. Push the battery in until it engages securely.
◁ The laser is ready to switch on.
2. Press the release button and hold it in this position.
3. Pull the battery out.
5.4

Switching the laser on and working in the horizontal plane

Check the accuracy of the laser tool before using it for important measuring tasks, especially if it has
been dropped or subjected to unusual influences or impacts etc.
8
English
Printed: 24.04.2018 | Doc-Nr: PUB / 5314337 / 000 / 01
2 m
(6 ft - 10 in)
−20 ℃ ... 50 ℃
(−4 ℉ ... 122 ℉)
−25 ℃ ... 60 ℃
(−13 ℉ ... 140 ℉)
0.25 kg
(0.55 lb)
IP66
5
6
7
2134493
*2134493*

Publicidad

Tabla de contenido
loading

Tabla de contenido