Technical Data; Rotating Laser Control Panel; Panneau De Commande Du Laser Rotatif; Panel De Control Del Láser Rotatorio - Hilti PR 2-HS Manual De Instrucciones

Ocultar thumbs Ver también para PR 2-HS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Designation
Battery
Tripod
Crank tripod (elevator tripod)
Crank tripod (elevator tripod)
Automatic tripod
Telescopic staffs

4 Technical data

Right of technical changes reserved.
PR 2-HS
Receiving range (diameter)
Accuracy
1
Laser class
Speed of rotation
Self-leveling range
Power source
Battery life
Operating temperature range
Storage temperature range (dry)
Protection class
Tripod thread
Weight (including the PRA 84)
Dimensions (L x W x H)
Drop test height
2
1 Influences such as particularly high temperature fluctuations, dampness, shock, dropping, etc. can affect accuracy. Unless stated
otherwise, the tool was adjusted or calibrated under standard ambient conditions (MIL-STD-810G).
2 The drop test was carried out from a tripod, dropping onto flat concrete under standard ambient conditions (MIL-STD-810G).
PRA 20 (02)
Detection range (area diameter)
Signal tone generator
Liquid-crystal display
Indicator range, distance from zero
Laser plane display range
Length of the receiving window
Center indication from top edge of casing
Marking notches
Time without detection before automatic power off
1 The drop test was carried out using the PRA 83 receiver holder, dropped onto flat concrete under standard ambient conditions
(MIL-STD-810G).
All manuals and user guides at all-guides.com
Short designation
PRA 84G
PUA 20
PUA 30
PA 921
PRA 90
PUA 50, PUA 55
With PRA 20 (02) laser receiver: 2...600 m (6.56...
1,968.5 ft)
At 10 meters: ± 0.5 mm
Class 2, 620-690 nm; < 1 mW (EN 60825-1:2007 / IEC
60825-1:2007); Class II (CFR 21 § 1040 (FDA)); Maxi-
mum power < 4.85 mW at ≧ 300 r.p.m.
300/min ± 10%
± 5°
7.2 V / 4.5 Ah Li‑ion battery
Temperature +25°C (+77 °F), Li‑ion battery: ≥ 30 h
-20...+50°C (−4...+122 °F)
-25...+60°C (−13...+140 °F)
IP 66 (in accordance with IEC 60529); Not in "charging
during operation" mode
⁵⁄₈" x 18
2.5 kg (5.51 lb)
200 mm (7.87") x 200 mm (7.87") x 230 mm (9.06")
1.5 m (4.92 ft)
With the PR 2-HS (typical): 2...600 m (6.56...1,968.5 ft)
3 volume levels plus mute setting
On both sides
± 52 mm
± 0.5 mm
120 mm (4.72")
75 mm (2.95")
On both sides
15 min
en
5

Publicidad

Tabla de contenido
loading