Initial Operation; Maintenance Work; Technical Data - Chamberlain LiftMaster SLY300 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20

INITIAL OPERATION

Check gate functionality manually when the drive has been
disengaged. Electrical operation is only possible with the control unit
that is supplied as standard.
Electrical connections: See control unit instructions.
Always ensure that the mechanical and electrical safety requirements
relevant to the given system are complied with. fig. 10

MAINTENANCE WORK

The drive mechanics are maintenance-free. Check at regular
intervals (monthly) that the gate hardware and the drive are all firmly
in place. Disengage the drive and check gate functionality. Only an
easy-running gate will work well with a drive. A drive is no substitute
for a poorly functioning gate.
A sliding gate can also be secured by implementing on-site
measures (fence, wall, etc.). See fig. 11.

TECHNICAL DATA

SLY300
Voltage IN
230Volt
Frequency
50Hz
Power
300W
Current rated
1,3A
Torque
8Nm
Capacitor
8μF
Therminal Overload
Protection
140°
Motor Speed
1400
Travel Speed
10,5
Duty Cycle
30
Working Temperatur
-20
O
C/ +55
Range
IP44
Protection Class
I
Degree of Protection
8
Weight
5m
approx. Gate Length
Max. Gate weight at
max. length (incl.
300kg
20% reserve)
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models SLY300/E/K, SLY500/E/K, SLY1000/E/K, SLY1800/E/K
Series are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .............................................2006/95/EC, 2004/108/EC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models , when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
January, 2009
SLY500
SLY1000
230Volt
230Volt
50Hz
50Hz
360W
480W
1,5A
2,1A
11Nm
20Nm
10μF
16μF
140°
140°
1400
1400
10,5
10.5
30
30
O
C
-20
O
C/ +55
O
C
-20
O
C/ +55
IP44
IP44
I
I
8
10
8m
10m
500kg
1000kg
conforms to the above Directives and Standard
© Chamberlain GmbH 2009
SLY1800
230Volt
50Hz
600W
2,6A
34Nm
20μF
140°
1400
8
30
O
C
-20
O
C - 55
O
C
IP44
I
12
12m
1800kg
s.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Liftmaster sly300 eLiftmaster sly300 kLiftmaster sly500Liftmaster sly500 eLiftmaster sly500 kLiftmaster sly1000 ... Mostrar todo

Tabla de contenido