When automatic equalisation is not completely finished within one day, it will
not resume the next day, the next equalisation session will take place as
determined by the day interval.
3.9 LEDs
LED indication:
permanent on
blinking
off
Regular operation
Not charging (*1)
Bulk
Absorption
Automatic equalisation
Float
Note (*1): The bulk LED will blink briefly every 3 seconds when the system is
powered but there is insufficient power to start charging.
Fault situations
Charger temperature too high
Charger over-current
Charger or panel over-voltage
Internal error (*3)
Note (*3): E.g. calibration and/or settings data lost, current sensor issue.
3.10 Connectivity
Bluetooth Smart (built-in): connect to a smartphone or tablet running iOS or
Android, see section 3.6 for the required software.
VE.Direct to USB cable (ASS030530000): connect to a PC a smartphone
with Android and USB On-The-Go support (requires additional USB OTG
cable), see section 3.6 for the required software.
VE.Direct to VE.Direct cable: connect to a MPPT Control or a Color Control
panel (BPP000300100R).
MPPT Control
8
LEDs
Bulk
LEDs
Bulk
Color Control
Absorption
Float
Absorption
Float