Steam time-out
CAUSE
This alarm is triggered when steam is produced
through the MCS where milk temperature probe
does not reach 30°C within 60 seconds.
EFFECT
Steam supply is locked; push DEL on display to
delete the alarm.
Type "ABP" alarms
Steam boiler time-out
CAUSE
This alarm is triggered when the steam boiler does
not reach the temperature of 40°C within 10 minu-
tes of turning on.
EFFECT
Boiler heating up is locked; push DEL on display
to delete the alarm.
Boiler probe interrupted
CAUSE
This alarm is triggered when boiler temperature
probe is out of the range.
EFFECT
Boiler heating up is locked; push DEL on display
to delete the alarm.
Boiler probe short circuit
This alarm is triggered when boiler temperature
probe is out of the range.
EFFECT
Boiler heating up is locked; push DEL on display
to delete the alarm.
Boiler high temperature
CAUSE
This alarm is triggered when boiler temperature
probe has exceeded 127°C.
EFFECT
Boiler heating up is locked; push DEL on display
to delete the alarm.
Steam probe interrupted
CAUSE
This alarm is triggered when MCS temperature
probe is out of the range.
EFFECT
MCS function is locked; push DEL on display to
delete the alarm.
Steam probe short circuit
CAUSE
This alarm is triggered when MCS temperature
probe is out of the range.
EFFECT
MCS function is locked; push DEL on display to
delete the alarm.
Gr.1 probe time-out
CAUSE
This alarm is triggered when group 1 does not
reach the temperature of 50°C within 5 minutes
of turning on.
EFFECT
Group 1 heating up is locked; push DEL on display
to delete the alarm.