NOTICE indicates special instructions which are important but
not related to hazards.
Carefully read and follow all safety instructions in this manual
and on pump.
HAZARDOUS PRESSURE:
WA R N I N G
Pump should not be operating
when water is not in use. Do
not run pump against closed
discharge. Release all system
pressure before working on
any component.
C A U T I O N Do not run pump dry. Fill pump with water
before starting or pump will be damaged.
This Inline Constant Pressure System is guaranteed by the
manufacturer. In the event of a product failure, it must be
returned to an authorized water system professional for
repairs. Warranty is void if repairs are not made by an
.
authorized technician
ELECTRICAL SAFETY
C A U T I O N
Make sure all ELECTRICAL POWER IS
OFF before connecting any electrical wires.
W A R N I N G
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor or
tank.
C A U T I O N
DO NOT touch an operating Inline
System. The surface of either the drive or pump unit
may be HOT. Allow all system components to cool
for thirty (30) minutes before handling.
Suitable for use on a circuit capable of delivering
not more than 5000 RMS symmetric amperes, 260
volt maximum.
The output connector on the drive is only
intended for use with the motor specified in the
Replacement Parts section of this manual.
Integral solid state short circuit protection does
not provide branch circuit protection. Branch circuit
protection must be provided in accordance with the
National Electric Code or Canadian Electric Code
and local codes.
Wire Inline System for
correct voltage. See
"Electrical Installation"
section of this manual and
Inline System nameplate.
Connect power supply
ground to ground terminal
in wiring compartment
before connecting power
supply.
Meet National Electrical
Code (NEC) or Canadian
Electrical Code (CEC) and
local codes for all wiring.
Follow all pump wiring
instructions provided in this
manual.
GENERAL SAFETY
The Franklin Electric Inline System is designed and built with
a NEMA 4 approved drive enclosure to protect the pump's
electronic components.
INLINE SYSTEm KEY FEATURES
SYSTEm FEATURES:
• Constant water pressure with a wide range of
settings. (10-80 psi, 0.7 - 5.5 bar)
• Pump speed is controlled to provide the optimum
performance without overloading the motor
• Product Power Rating: 1.2 hp (0.9 kW)
• Low current motor start-up (soft-starting)
• Quiet operation
• Single pump/motor/drive controller design
• Compact footprint, 19 in x 8 in (480 mm x 200 mm)
• Shipping weight: 50 lbs (22.7 kg)
PUmP FEATURES:
• Operates on a wide range of flows from flooded
suction to 35 gpm (135 lpm)
• Requires minimum incoming pressure of 3 psi
(0.2 bar) Exception: Cisterns may be flooded suction
without vortexing
• Increases incoming pressure by up to 60 psi (4.1 bar)
• Stainless steel construction for all wetted surfaces
DRIvE CONTROLLER PROTECTION FEATURES:
• No in-rush (power-on transient) current
• Over pressure shut off optional
(See Replacement Parts Section)
• Low water shut off
• Locked pump detection/shut off
• Water over-temperature shut off
• High voltage/lightning surge protection
• Low line voltage protection
• Motor under and overload protection
• Open and short circuit protection
• NEMA 4 enclosure
INSPECT YOUR SHIPmENT
All Franklin Electric Inline Systems are carefully tested, inspected,
and packaged to ensure their arrival in perfect condition. When
the pump is received, examine it closely to make sure there is
no damage that may have occurred in shipping. If damage is
evident, report this immediately to your shipping carrier and
product dealer. The shipping carrier assumes full responsibility
for the shipment's safe arrival. Any claim for damage to the
shipment, either visible or concealed, must be made through the
shipping carrier first.
PACKAGE INCLUDES:
• Inline 1100 Constant Pressure System pump
and controller unit
• Pressure sensor and boot
• Sensor adjustment tool
• Installation manual